elescope----------------------------------------------------------
Image Erect
Magnification 30×
Effective aperture 45mm (EDM 48mm)
Resolving power 4″
Field of view 1°30′
Minimum focus 1m
Stadia ratio 100
Sight distance precision ≤0.4%D
Tube length 154mm
Angle Measurement ------------------------------------------
Measuring method Photoelectric detection by incremental encoder
Dia of circle (vertical, horizontal) 79mm
Minimum reading 1″/5″Selectable
Detection method Horizontal: Dual
Vertical :Dual
Measuring unit 360°/400gon/6400mil Selectable
Vertical angle0° Zenith0°/Horizontal0°Selectable
Accuracy NTS-352R:2″
NTS-355R:5″
Vial ----------------------------------------------------------
Plate vial 30″/2mm
Circular vial 8′/2mm
Vertical Compensator----------------------------------------------------
System Liquid-electric detection/plate vial
Compensation range ±3′
Resolving power 1″
Optical Plummet------------------------------------------------
Image Erect
Magnification 3×
Focusing range 0.5m~∝
Field of view 5°
Display ---------------------------------------------------------------
Type LCD,Four lines,digital
Data Communication---------------------------------------------
Port RS-232C
On-board Battery-----------------------------------------------
Power resource Rechargeable Ni-H battery
Voltage DC6V
Type of battery NB-20B Battery
NB—20C Battery (Selectable)
Continuous operation time 8hrs(small battery)
10hrs(big battery)
Operation Environment ----------------------------------------------
Operating temperature -20°~+50℃
Size & weight ------------------------------------------------
Dimension 160×150×330mm
Weight (Exclude Battery) 5.2kg
|